Data Centre |
|
|
|
|
Our servers are located in carrier-neutral data centres in Docklands, London. We use exclusively
Redbus data centres, due to their class-leading 100% SLA, security and power facilities. Redbus also
has the advantage of being carrier-neutral, allowing us to peer with several transit providers for
network redundancy.
|
 |
Physical Security
When it comes to security, we refuse to compromise. All data centres feature totally comprehensive
24/7 security to keep equipment 100% safe. This means our customers have the protection of security
barriers, 24x7x365 monitoring by on-site personnel to include visual verification of all persons
entering the building, CCTV video camera surveillance and a security breach alarm provides the control
room with information.
Access
Access to the buildings, data floors and individual area’s are via individually programmed Proximity
Access Cards (PAC), usage of the PAC is logged centrally by time and date. The cards cannot be used by
anyone else, whenever you swipe your card tag over the sensors to gain access to the building, your
digital photograph will be displayed on our security systems which are continuously monitored by our
on-site technicians. The technicians will then verify the information and only when satisfied, allow
access.
Power
Our policy guarantees all our customers a redundant high-capacity, stable and reliable power supply,
with easy scalable expansion in the future. A minimum of 1Kw per square metre secure power is available,
with power isolated between customer and maintained indefinitely, plus on-site generation which can deal
with both customer and plant load whilst recharging the UPS.
All our facilities are built to at least an N+1 standard; put simply, this means that if two generators
are required to provide non-stop power, then there’ll be three installed. So rather than guaranteeing
99.99% availability, the guarantee is 100%.
Fire Detection and Suppression
Very Early Smoke Detection Apparatus (VESDA) is installed in every facility. These highly sensitive
aspirating smoke detectors are linked to the Building Management system which is monitored continually
from a network operations centre, provide very early detection to help avoid fire, loss and business
disruption. This is coupled with a gas based fire retardant that is environmentally friendly, to put out
fires instantly, without damaging equipment.
Air Conditioning
To ensure optimum performance, all data floors are maintained at a constant 21°C ± 2°C and relative
humidity is kept at 50% ± 10%. Both are continually monitored via the BMS.
Building Management System (BMS)
All facilities operate computerised building management systems that monitor and remotely operate sensors
covering electrical, mechanical, fire detection and leak detection systems.
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
 |